Public Reports Air & Water Database Public Reports Public Reports Air & Water Database Public Reports

Utah SNOTEL Site Mammoth-Cottonwood (612) - Sensors

2025-September-04 NRCS National Water and Climate Center

Daily sensors report a summary value for the previous day.

Hourly sensors report a summary value for the previous hour.

Instantaneous sensors report a single observation on the hour.

Instantaneous sensors are included with both Daily and Hourly sensor selections.

Instantaneous sensors for a Daily sensor selections are the midnight observation.

*The use of a particular manufacturer's instrument does not consitute an endorsement of that instrument or manufacturer.

Header Code Element Func Unit Instrument Start End Comment
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Druck 2021-10-14 present Adjusted offset - Joel Burley
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Druck 2021-03-18 2021-10-14 GOES upgrade. Switch to Eng units.
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Druck 2019-07-22 2021-03-18 replaced transducer
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2018-01-02 2019-07-22 reset offset
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2016-11-29 2018-01-02 update offset based on recent data
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2015-07-24 2016-11-29 moved shelter
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2012-09-19 2015-07-24 updated by prof_load
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2012-08-27 2012-09-19 updated by prof_load
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2012-06-22 2012-08-27 rezero
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2011-05-20 2012-06-22 turned off profile
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2009-09-25 2011-05-20 rezero
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2007-07-30 2009-09-25 zero new druck 100" installed 7/25/07
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2006-06-13 2007-07-30 zero after meltout
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2005-10-17 2006-06-13 rezero
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2004-10-18 2005-10-17 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2003-09-08 2004-10-18 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2002-08-05 2003-09-08 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2001-11-26 2002-08-05 rezero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2001-10-29 2001-11-26 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 2000-05-15 2001-10-29 zero sensor after meltout
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1999-09-01 2000-05-15 zero new 10' hypalon which replaces 3-ca steel pillows
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1999-06-07 1999-09-01 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1998-10-26 1999-06-07 re-zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1998-08-13 1998-10-26 re-zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1998-05-28 1998-08-13 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1997-09-05 1998-05-28 re-zero
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1997-05-27 1997-09-05 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1997-02-21 1997-05-27 reset after ducer change
WTEQ.I-1 Snow Water Equivalent OBS In Pressure Transducer - 100" Sensotec 1997-02-20 1997-02-21 bob changed unstable cic6100 for st100
WTEQ.I-1 Snow Water Equivalent OBS In 100" Cic - Unknown 1996-09-23 1997-02-20 re-zero after gravel added
WTEQ.I-1 Snow Water Equivalent OBS In 100" Cic - Unknown 1995-10-16 1996-09-23 zero sensor
WTEQ.I-1 Snow Water Equivalent OBS In 100" Cic - Unknown 1995-07-20 1995-10-16 maintenance caused change in readings
WTEQ.I-1 Snow Water Equivalent OBS In 100" Cic - Unknown 1993-10-01 1995-07-20
WTEQ.I-1 Snow Water Equivalent OBS In Undefined Sensor - Linear Equation 1978-10-01 1993-10-01 Unconfirmed from archives
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2025-07-10 present precip recharged
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2024-10-01 2025-07-10 new-water-year offset, 2024-10-01 00:21
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2024-08-26 2024-10-01 precip recgarged
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2023-10-01 2024-08-26 new-water-year offset, 2023-10-01 00:18
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2022-10-01 2023-10-01 new-water-year offset, 2022-10-01 00:18
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2022-06-10 2022-10-01 NAM offset. Joel Burley
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2021-10-01 2022-06-10 new-water-year offset, 2021-10-01 00:41
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2021-07-30 2021-10-01 Yearly Maintenance, recharge. Joel Burley
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2021-03-18 2021-07-30 GOES upgrade. Switch to Eng units.
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2020-10-01 2021-03-18 new-water-year offset, 2020-10-01 00:03
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2020-08-18 2020-10-01 2020 NAM
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2019-10-01 2020-08-18 new-water-year offset, 2019-10-01 00:10
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Druck 2019-07-22 2019-10-01 recharge offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2019-07-22 2019-07-22 recharge offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2018-10-10 2019-07-22 recharge offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2018-10-01 2018-10-10 new-water-year offset, 2018-10-01 00:03
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2017-10-01 2018-10-01 new-water-year offset, 2017-10-01 00:09
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2017-07-10 2017-10-01 recharged
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2016-10-01 2017-07-10 new-water-year offset, 2016-10-01 00:20
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2016-06-30 2016-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2015-10-01 2016-06-30 new-water-year offset, 2015-10-01 00:32
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2015-07-24 2015-10-01 recharged site
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2014-10-01 2015-07-24 new-water-year offset, 2014-10-01 00:18
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2014-07-29 2014-10-01 recharged site
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2013-10-01 2014-07-29 new-water-year offset, 2013-10-01 00:10
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2013-08-01 2013-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2012-10-01 2013-08-01 new-water-year offset, 2012-10-01 00:12
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2012-09-19 2012-10-01 updated by prof_load
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2012-08-27 2012-09-19 updated by prof_load
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2012-07-03 2012-08-27 turned off profile due to flagging
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2012-07-02 2012-07-03 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2011-10-01 2012-07-02 new-water-year offset, 2011-10-01 00:15
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2011-09-26 2011-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2010-10-01 2011-09-26 new-water-year offset, 2010-10-01 00:32
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2010-08-03 2010-10-01 Recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2009-10-01 2010-08-03 new-water-year offset, 2009-10-01 00:12
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2009-07-17 2009-10-01 Recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2008-10-01 2009-07-17 new-water-year offset, 2008-10-01 00:07
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2008-07-14 2008-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2007-10-01 2008-07-14 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2007-06-14 2007-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2006-10-01 2007-06-14 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2006-09-06 2006-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2005-10-01 2006-09-06 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2005-06-30 2005-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2004-10-14 2005-06-30 tim re-recharged and replaced plumbing
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2004-10-01 2004-10-14 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2004-09-16 2004-10-01 reset after ducer change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2004-09-14 2004-09-16 randy changed unstable st100 on 9/10/04
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2004-07-14 2004-09-14 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2003-10-01 2004-07-14 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2003-07-14 2003-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2002-10-01 2003-07-14 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2002-08-26 2002-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2001-10-01 2002-08-26 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2001-09-04 2001-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2000-10-01 2001-09-04 New water year offset
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 2000-09-11 2000-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1999-10-01 2000-09-11 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1999-09-01 1999-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1998-10-01 1999-09-01 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1998-09-21 1998-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1997-10-01 1998-09-21 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1997-09-05 1997-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1997-02-21 1997-09-05 reset after ducer change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1996-10-01 1997-02-21 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1996-09-09 1996-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1995-10-01 1996-09-09 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1995-07-20 1995-10-01 recharge
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1994-10-01 1995-07-20 New year offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1994-09-19 1994-10-01 Offset change
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1993-10-06 1994-09-19
PREC.I-1 Precipitation Accumulation OBS In Pressure Transducer - 100" Sensotec 1993-10-01 1993-10-06
PREC.I-1 Precipitation Accumulation OBS In Precipitation - Unknown Sensor 1992-10-01 1993-10-01
PREC.I-1 Precipitation Accumulation OBS In Precipitation - Unknown Sensor 1978-10-01 1992-10-01 Unconfirmed from archives
TOBS.I-1 Air Temperature OBS Degc Air Temp - Apogee St300 2025-07-09 present ST300 installed on 07/09/2025
TOBS.I-1 Air Temperature OBS Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TOBS.I-1 Air Temperature OBS Degc Air Temp - Ysi 44211a 2012-08-28 2021-03-18 updated by prof_load
TOBS.I-1 Air Temperature OBS Degc Air Temp - Ysi 44211a 2005-07-05 2012-08-28 extended range sensor installed 6/28/05 during csi upgrade
TOBS.I-2 Air Temperature OBS Degc Air Temp - Unknown Sensor 1993-10-01 2005-07-05
TOBS.I-2 Air Temperature OBS Degc Air Temp - Unknown Sensor 1985-10-01 1993-10-01 Unconfirmed from archives
TOBS.I-2 Air Temperature OBS Degc Air Temp - Unknown Sensor 1978-10-01 1985-10-01 Unconfirmed from archives
TOBS.I-98 Air Temperature OBS Degc Air Temp - Ysi 44211a 2025-07-09 present Installed ST300. Moved old YSI to ordinal 98
TOBS.I-99 Air Temperature OBS Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TOBS.I-99 Air Temperature OBS Degc Air Temp - Ysi 44211a 2012-08-28 2021-03-18 updated by prof_load
TOBS.I-99 Air Temperature OBS Degc Air Temp - Ysi 44211a 2005-07-05 2012-08-28 extended range sensor installed 6/28/05 during csi upgrade
TMAX.D-1 Air Temperature MAX Degc Air Temp - Apogee St300 2025-07-09 present ST300 installed on 07/09/2025
TMAX.D-1 Air Temperature MAX Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TMAX.D-1 Air Temperature MAX Degc Air Temp - Ysi 44211a 2013-02-06 2021-03-18 updated by prof_load
TMAX.D-1 Air Temperature MAX Degc Air Temp - Ysi 44211a 2005-07-05 2013-02-06 extended range sensor installed 6/28/05 during csi upgrade
TMAX.D-2 Air Temperature MAX Degc Air Temp - Unknown Sensor 1993-10-01 2005-07-05
TMAX.D-2 Air Temperature MAX Degc Air Temp - Unknown Sensor 1985-10-01 1993-10-01 Unconfirmed from archives
TMAX.D-98 Air Temperature MAX Degc Air Temp - Ysi 44211a 2025-07-09 present Installed ST300. Moved old YSI to ordinal 98
TMAX.D-99 Air Temperature MAX Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TMAX.D-99 Air Temperature MAX Degc Air Temp - Ysi 44211a 2013-02-06 2021-03-18 updated by prof_load
TMAX.D-99 Air Temperature MAX Degc Air Temp - Ysi 44211a 2005-07-05 2013-02-06 extended range sensor installed 6/28/05 during csi upgrade
TMIN.D-1 Air Temperature MIN Degc Air Temp - Apogee St300 2025-07-09 present ST300 installed on 07/09/2025
TMIN.D-1 Air Temperature MIN Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TMIN.D-1 Air Temperature MIN Degc Air Temp - Ysi 44211a 2013-02-06 2021-03-18 updated by prof_load
TMIN.D-1 Air Temperature MIN Degc Air Temp - Ysi 44211a 2005-07-05 2013-02-06 extended range sensor installed 6/28/05 during csi upgrade
TMIN.D-2 Air Temperature MIN Degc Air Temp - Unknown Sensor 1993-10-01 2005-07-05
TMIN.D-2 Air Temperature MIN Degc Air Temp - Unknown Sensor 1985-10-01 1993-10-01 Unconfirmed from archives
TMIN.D-98 Air Temperature MIN Degc Air Temp - Ysi 44211a 2025-07-09 present Installed ST300. Moved old YSI to ordinal 98
TMIN.D-99 Air Temperature MIN Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TMIN.D-99 Air Temperature MIN Degc Air Temp - Ysi 44211a 2013-02-06 2021-03-18 updated by prof_load
TMIN.D-99 Air Temperature MIN Degc Air Temp - Ysi 44211a 2005-07-05 2013-02-06 extended range sensor installed 6/28/05 during csi upgrade
TAVG.D-1 Air Temperature AVG Degc Air Temp - Apogee St300 2025-07-09 present ST300 installed on 07/09/2025
TAVG.D-1 Air Temperature AVG Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TAVG.D-1 Air Temperature AVG Degc Air Temp - Ysi 44211a 2005-07-05 2021-03-18 extended range sensor installed 6/28/05 during csi upgrade
TAVG.D-2 Air Temperature AVG Degc Air Temp - Unknown Sensor 1993-10-01 2005-07-05
TAVG.D-2 Air Temperature AVG Degc Air Temp - Unknown Sensor 1985-10-01 1993-10-01 Unconfirmed from archives
TAVG.D-98 Air Temperature AVG Degc Air Temp - Ysi 44211a 2025-07-09 present Installed ST300. Moved old YSI to ordinal 98
TAVG.D-99 Air Temperature AVG Degc Air Temp - Ysi 44211a 2021-03-18 2025-07-09 GOES upgrade. Switch to Eng units.
TAVG.D-99 Air Temperature AVG Degc Air Temp - Ysi 44211a 2005-07-05 2021-03-18 extended range sensor installed 6/28/05 during csi upgrade
SNWD.I-1 Snow Depth OBS In Snow Depth - Sommer Ush-9 2024-04-18 present adjusted offset by -14 for new USH9 install. -Kori Mooney
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2022-10-30 2024-04-18 adjusted offset. Joel Burley
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2021-03-18 2022-10-30 GOES upgrade. Switch to Eng units.
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2015-07-24 2021-03-18 moved shelter
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2012-09-19 2015-07-24 updated by prof_load
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2012-02-17 2012-09-19 replaced sensor
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2008-09-22 2012-02-17 re-zero
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2007-08-13 2008-09-22 re-zero
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2007-07-17 2007-08-13 re-zero sensor
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2005-07-06 2007-07-17 zero new sensor
SNWD.I-1 Snow Depth OBS In Undefined Sensor - Linear Equation 2001-11-01 2005-07-06 Sensor label change
SNWD.I-1 Snow Depth OBS In Sei 1999-10-18 2001-11-01 re-zero sensor
SNWD.I-1 Snow Depth OBS In Sei 1999-09-01 1999-10-18 zero new sensor on new met tower
SNWD.I-1 Snow Depth OBS In Sei 1996-09-06 1999-09-01 zero sensor
SNWD.I-1 Snow Depth OBS In Sei 1996-08-26 1996-09-06 ed installed judd snow depth sensor 8/21/96
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2021-08-10 present sensor repaired or replaced
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2021-04-01 2021-08-10 Wiring issue -- this channel is reading temperature.
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2012-12-14 2021-04-01 updated by prof_load
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-12-12 2012-12-14 silt
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-11-09 2007-12-12 silt
SMS.I-1:-2 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 2007-11-09 silt
SMS.I-1:-8 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2012-12-14 present updated by prof_load
SMS.I-1:-8 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-12-12 2012-12-14 silt
SMS.I-1:-8 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-11-09 2007-12-12 silt
SMS.I-1:-8 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 2007-11-09 silt
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2023-10-04 present sensor doing ok. unforced suspect
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2023-07-07 2023-10-04 force suspect
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2012-12-14 2023-07-07 updated by prof_load
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-12-12 2012-12-14 silt
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2007-11-09 2007-12-12 silt
SMS.I-1:-20 Soil Moisture Percent OBS Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 2007-11-09 silt
STO.I-1:-2 Soil Temperature OBS Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2021-08-10 present Sensor repaired or replaced
STO.I-1:-2 Soil Temperature OBS Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2021-04-01 2021-08-10 Wiring Issue -- this channel is reading moisture
STO.I-1:-2 Soil Temperature OBS Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 2021-04-01
STO.I-1:-8 Soil Temperature OBS Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
STO.I-1:-20 Soil Temperature OBS Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
SAL.I-1:-2 Salinity OBS Gram/l Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
SAL.I-1:-8 Salinity OBS Gram/l Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
SAL.I-1:-20 Salinity OBS Gram/l Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
RDC.I-1:-2 Real Dielectric Constant OBS Unitless Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
RDC.I-1:-8 Real Dielectric Constant OBS Unitless Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
RDC.I-1:-20 Real Dielectric Constant OBS Unitless Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) 2002-09-13 present
BATT.I-1 Battery OBS Volt Undefined Sensor - Linear Equation 2021-03-18 present GOES upgrade. Switch to Eng units.
BATT.I-1 Battery OBS Volt Undefined Sensor - Linear Equation 1993-10-01 2021-03-18
BATT.I-1 Battery OBS Volt Undefined Sensor - Linear Equation 1978-10-01 1993-10-01 Unconfirmed from archives