Header Code | Element | Func | Unit | Instrument | Start | End | Comment |
---|---|---|---|---|---|---|---|
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2019-08-05 | present | adjusting offset-EA |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2016-10-17 | 2019-08-05 | Zero hypalon pillow. |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2016-09-06 | 2016-10-17 | adjusting zero |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2016-06-20 | 2016-09-06 | txd replaced for recalibration, zeroing new txd |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2013-08-08 | 2016-06-20 | hypalon pillow, correct instrument label |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2013-07-29 | 2013-08-08 | Zero hypalon pillow |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2012-10-23 | 2013-07-29 | Zero hypalon pillow |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2012-09-20 | 2012-10-23 | Zero hypalon pillow, replaced txd for recal |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2012-08-03 | 2012-09-20 | Zero hypalon pillow, replaced txd for recal |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2010-10-18 | 2012-08-03 | Zero hypalon pillow |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2010-08-25 | 2010-10-18 | pillow found rolled up on site visit, no leaks present 7/29/10 |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2010-06-17 | 2010-08-25 | set upper pillow profile active |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2009-10-06 | 2010-06-17 | set upper pillow profile inactive |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2008-09-16 | 2009-10-06 | Site visit, added precip fluid. |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2003-08-25 | 2008-09-16 | updated by change_state |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2001-09-28 | 2003-08-25 | Zero hypalon pillow |
WTEQ.I-1 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2001-09-19 | 2001-09-28 | New hypalon pillow 100" txd |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2019-08-05 | present | adjusting offset-EA |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2016-10-20 | 2019-08-05 | Zero backup transducer on hypalon pillow. |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2016-06-20 | 2016-10-20 | txd replaced for recal, zeroing new txd |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Druck | 2013-08-08 | 2016-06-20 | backup hypalon pillow, correct instrument label |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2013-07-29 | 2013-08-08 | Zero backup pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2012-08-03 | 2013-07-29 | Zero backup pillow, replaced txd for recal |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2010-10-25 | 2012-08-03 | Zero backup txd on hypalon pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Druck 0-69.4" | 2008-09-16 | 2010-10-25 | Zero backup txd on hypalon pillow, site visit, added precip fluid. |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2005-10-25 | 2008-09-16 | Zero backup txd on hypalon pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2003-07-29 | 2005-10-25 | Zero backup txd on hypalon pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2002-10-18 | 2003-07-29 | Zero backup txd on hypalon pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2001-09-28 | 2002-10-18 | Zero backup txd on hypalon pillow |
WTEQ.I-2 | Snow Water Equivalent | OBS | In | Pressure Transducer - 100" Sensotec | 2001-09-19 | 2001-09-28 | Backup txd on hypalon pillow |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2025-10-01 | present | new-water-year offset, 2025-10-01 00:30 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2025-07-22 | 2025-10-01 | recharge offset-EA |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2024-10-01 | 2025-07-22 | new-water-year offset, 2024-10-01 00:31 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2024-09-27 | 2024-10-01 | Recharge offset, AP |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2023-10-01 | 2024-09-27 | new-water-year offset, 2023-10-01 00:28 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2023-09-25 | 2023-10-01 | recharge offset correction 2023 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2023-09-22 | 2023-09-25 | recharge offset 2023 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2022-10-01 | 2023-09-22 | new-water-year offset, 2022-10-01 00:28 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2022-08-01 | 2022-10-01 | recharge offset, DJT |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2021-10-01 | 2022-08-01 | new-water-year offset, 2021-10-01 00:41 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2021-09-10 | 2021-10-01 | recharge offset - MR |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2020-10-01 | 2021-09-10 | new-water-year offset, 2020-10-01 00:05 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2019-10-01 | 2020-10-01 | new-water-year offset, 2019-10-01 00:07 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2019-09-18 | 2019-10-01 | recharge 2019 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2018-10-09 | 2019-09-18 | adjusting offset-EA |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2018-10-01 | 2018-10-09 | new-water-year offset, 2018-10-01 00:07 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2018-09-05 | 2018-10-01 | recharge offset 2018-EA |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2018-01-10 | 2018-09-05 | Air block in plumbing line, corrected on 12/22, responded to new precip on 1/10, removing suspect. |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2017-11-20 | 2018-01-10 | Bad data, suspecting. |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2017-10-01 | 2017-11-20 | new-water-year offset, 2017-10-01 00:47 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2016-10-01 | 2017-10-01 | new-water-year offset, 2016-10-01 00:49 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2016-06-20 | 2016-10-01 | recharge offset, 2016, & txd replaced for recal |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2015-10-01 | 2016-06-20 | new-water-year offset, 2015-10-01 00:58 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2015-07-29 | 2015-10-01 | recharge offset, 2015 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2014-10-01 | 2015-07-29 | new-water-year offset, 2014-10-01 00:50 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2014-09-12 | 2014-10-01 | Recharge only |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2013-10-01 | 2014-09-12 | new-water-year offset, 2013-10-01 00:53 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Druck | 2013-08-08 | 2013-10-01 | prec, correct instrument label |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2013-08-01 | 2013-08-08 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2012-10-26 | 2013-08-01 | replaced prec txd for recal 8/1/12 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2012-10-01 | 2012-10-26 | new-water-year offset, 2012-10-01 00:30 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2012-08-03 | 2012-10-01 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2011-10-01 | 2012-08-03 | new-water-year offset, 2011-10-01 03:27 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2011-09-28 | 2011-10-01 | adjust prec for edits after leak fixed |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2011-08-04 | 2011-09-28 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2010-10-01 | 2011-08-04 | new-water-year offset, 2010-10-01 02:36 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2010-08-02 | 2010-10-01 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2009-10-01 | 2010-08-02 | new-water-year offset, 2009-10-01 00:28 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2009-08-26 | 2009-10-01 | Recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2008-10-01 | 2009-08-26 | new-water-year offset, 2008-10-01 00:10 |
PREC.I-1 | Precipitation Accumulation | OBS | In | Druck 0-69.4" | 2008-09-16 | 2008-10-01 | Recharge. |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2007-10-01 | 2008-09-16 | updated by change_state |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2007-09-28 | 2007-10-01 | Recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2006-10-01 | 2007-09-28 | New water year offset |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2005-10-25 | 2006-10-01 | Adjust for new 100" Druck txd |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2005-10-01 | 2005-10-25 | New water year offset |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2005-09-08 | 2005-10-01 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2004-10-01 | 2005-09-08 | New water year offset |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2004-08-23 | 2004-10-01 | Recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2004-08-23 | 2004-08-23 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2003-10-01 | 2004-08-23 | New water year offset |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2003-07-28 | 2003-10-01 | recharge |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2002-10-18 | 2003-07-28 | Recharge & new Druck txd on precip |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2002-10-01 | 2002-10-18 | New water year offset |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2001-10-01 | 2002-10-01 | New year offset change |
PREC.I-1 | Precipitation Accumulation | OBS | In | Pressure Transducer - 100" Sensotec | 2001-09-19 | 2001-10-01 | New precip 100" txd |
PREC.I-2 | Precipitation Accumulation | OBS | In | Precipitation - Unknown Sensor | 2003-07-29 | 2005-10-25 | Tipping bucket cumulative inches |
PREC.I-2 | Precipitation Accumulation | OBS | In | Precipitation - Unknown Sensor | 2002-10-18 | 2003-07-29 | Tipping bucket cumulative inches |
TOBS.I-1 | Air Temperature | OBS | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, AP |
TOBS.I-1 | Air Temperature | OBS | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature current |
TOBS.I-3 | Air Temperature | OBS | Degc | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | Current RH temp deg. C |
TOBS.I-98 | Air Temperature | OBS | Degc | Air Temp - Ysi 44211a | 2024-09-25 | present | YSI extended range, hourly, 9th order correction equation is in logger program. AP |
TOBS.I-99 | Air Temperature | OBS | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature current |
TMAX.D-1 | Air Temperature | MAX | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 install, daily max, AP |
TMAX.H-1 | Air Temperature | MAX | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, Hourly Max, AP |
TMAX.D-1 | Air Temperature | MAX | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature max |
TMAX.D-2 | Air Temperature | MAX | Degc | Air Temp - Ysi 44211a | 2009-10-29 | 2024-09-25 | 24 hour max air temp deg. C |
TMAX.D-2 | Air Temperature | MAX | Degc | Air Temp - Ysi 44211a | 2002-10-18 | 2009-10-15 | 24 hour max air temp deg. C |
TMAX.H-3 | Air Temperature | MAX | Degc | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | RH temp hourly max deg. C |
TMAX.D-98 | Air Temperature | MAX | Degc | Air Temp - Ysi 44211a | 2024-09-25 | present | YSI extended range, daily max, 9th order correction equation is in logger program. AP |
TMAX.D-99 | Air Temperature | MAX | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature max |
TMIN.D-1 | Air Temperature | MIN | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, daily min, AP |
TMIN.H-1 | Air Temperature | MIN | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, Hourly MIN, AP |
TMIN.D-1 | Air Temperature | MIN | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature min |
TMIN.D-2 | Air Temperature | MIN | Degc | Air Temp - Ysi 44211a | 2009-10-29 | 2024-09-25 | 24 hour min air temp deg. C |
TMIN.D-2 | Air Temperature | MIN | Degc | Air Temp - Ysi 44211a | 2002-10-18 | 2009-10-15 | 24 hour min air temp deg. C |
TMIN.H-3 | Air Temperature | MIN | Degc | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | RH temp hourly min deg. C |
TMIN.D-98 | Air Temperature | MIN | Degc | Air Temp - Ysi 44211a | 2024-09-25 | present | YSI extended range, daily min, 9th order correction equation is in logger program. AP |
TMIN.D-99 | Air Temperature | MIN | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature min |
TAVG.D-1 | Air Temperature | AVG | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, daily avg, AP |
TAVG.H-1 | Air Temperature | AVG | Degc | Air Temp - Apogee St300 | 2024-09-25 | present | ST-300 Install, Hourly AVG, AP |
TAVG.D-1 | Air Temperature | AVG | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature avg |
TAVG.D-2 | Air Temperature | AVG | Degc | Air Temp - Ysi 44211a | 2009-10-29 | 2024-09-25 | 24 hour avg air temp deg. C |
TAVG.D-2 | Air Temperature | AVG | Degc | Air Temp - Ysi 44211a | 2002-10-18 | 2009-10-15 | 24 hour avg air temp deg. C |
TAVG.H-3 | Air Temperature | AVG | Degc | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | RH temp hourly avg deg. C |
TAVG.D-98 | Air Temperature | AVG | Degc | Air Temp - Ysi 44211a | 2024-09-25 | present | YSI extended range, daily avg, 9th order correction equation is in logger program. AP |
TAVG.D-99 | Air Temperature | AVG | Degc | Air Temp - Ysi 44211a | 2001-09-19 | 2024-09-25 | Ext. range temperature avg |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Sommer Ush-9 | 2024-09-25 | present | Sommer USH9 installation |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2021-09-13 | 2024-09-25 | Update offset after conv to CR1000X - MR |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2021-09-10 | 2021-09-13 | Update to CR1000X - MR |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2017-11-16 | 2021-09-10 | reactivating upper limit profile. |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2017-09-21 | 2017-11-16 | exceeded upper limit profile |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2015-10-14 | 2017-09-21 | Zero depth sensor, 10/14/15 |
SNWD.I-1 | Snow Depth | OBS | In | Snow Depth - Judd | 2014-10-20 | 2015-10-14 | Zero Judd snow depth inches. |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2011-09-21 | 2014-10-20 | reloaded upper depth profile |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2011-06-20 | 2011-09-21 | shifted upper depth profile up by *1.1 |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2009-10-13 | 2011-06-20 | set upper depth profile active |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2009-10-06 | 2009-10-13 | set upper depth profile inactive |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2008-03-20 | 2009-10-06 | Scaled Upper limit * 0.65 |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2004-08-23 | 2008-03-20 | Zero depth inches |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2003-10-30 | 2004-08-23 | Zero depth inches |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2003-07-29 | 2003-10-30 | Zero Judd depth with new board |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2001-09-28 | 2003-07-29 | Zero depth inches |
SNWD.I-1 | Snow Depth | OBS | In | Undefined Sensor - Linear Equation | 2001-09-19 | 2001-09-28 | New Judd depth inches |
PRCP.H-1 | Precipitation Increment | DLT | In | Precipitation - Unknown Sensor | 2001-09-19 | 2005-10-25 | Hourly tipping precip (not installed) |
PRCP.D-2 | Precipitation Increment | DLT | In | Precipitation - Unknown Sensor | 2002-10-18 | 2005-10-25 | 24 hour tipping bucket catch |
SMS.I-1:-2 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2018-03-05 | present | forced suspect |
SMS.I-1:-2 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | 2018-03-05 | silt |
SMS.I-1:-2 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-10-25 | silt |
SMS.I-1:-2 | Soil Moisture Percent | OBS | Pct | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | silt |
SMS.I-1:-8 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2018-10-12 | present | forced suspect |
SMS.I-1:-8 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | 2018-10-12 | silt |
SMS.I-1:-8 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | silt |
SMS.I-1:-8 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | silt |
SMS.I-1:-8 | Soil Moisture Percent | OBS | Pct | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | silt |
SMS.I-1:-20 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | silt |
SMS.I-1:-20 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | silt |
SMS.I-1:-20 | Soil Moisture Percent | OBS | Pct | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | silt |
SMS.I-1:-20 | Soil Moisture Percent | OBS | Pct | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | silt |
STO.I-1:-2 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
STO.I-1:-2 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-10-25 | |
STO.I-1:-2 | Soil Temperature | OBS | Degc | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
STO.I-1:-8 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2018-10-12 | present | forced suspect |
STO.I-1:-8 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | 2018-10-12 | |
STO.I-1:-8 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
STO.I-1:-8 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
STO.I-1:-8 | Soil Temperature | OBS | Degc | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
STO.I-1:-20 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
STO.I-1:-20 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
STO.I-1:-20 | Soil Temperature | OBS | Degc | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
STO.I-1:-20 | Soil Temperature | OBS | Degc | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
SAL.I-1:-2 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
SAL.I-1:-2 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-10-25 | |
SAL.I-1:-2 | Salinity | OBS | Gram/l | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
SAL.I-1:-8 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
SAL.I-1:-8 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
SAL.I-1:-8 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
SAL.I-1:-8 | Salinity | OBS | Gram/l | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
SAL.I-1:-20 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
SAL.I-1:-20 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
SAL.I-1:-20 | Salinity | OBS | Gram/l | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
SAL.I-1:-20 | Salinity | OBS | Gram/l | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
RDC.I-1:-2 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
RDC.I-1:-2 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-10-25 | |
RDC.I-1:-2 | Real Dielectric Constant | OBS | Unitless | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
RDC.I-1:-8 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
RDC.I-1:-8 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
RDC.I-1:-8 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
RDC.I-1:-8 | Real Dielectric Constant | OBS | Unitless | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
RDC.I-1:-20 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-10-25 | present | |
RDC.I-1:-20 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2005-09-09 | 2005-10-25 | |
RDC.I-1:-20 | Real Dielectric Constant | OBS | Unitless | Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) | 2001-10-31 | 2005-09-09 | |
RDC.I-1:-20 | Real Dielectric Constant | OBS | Unitless | Hydraprobe Analog (5.0 Volt) - 1 Of 4 | 2001-09-19 | 2001-10-31 | |
BATX.D-1 | Battery | MAX | Volt | Undefined Sensor - Linear Equation | 2013-09-19 | 2024-09-25 | 24 hour max 545 battery |
BATX.D-1 | Battery | MAX | Volt | Undefined Sensor - Linear Equation | 2009-10-29 | 2013-09-19 | 24 hour max 545 battery |
BATX.D-1 | Battery | MAX | Volt | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-29 | 24 hour max 545 battery |
BATX.D-1 | Battery | MAX | Volt | Undefined Sensor - Linear Equation | 2002-10-18 | 2005-10-25 | 24 hour max 545 battery |
BATX.H-1 | Battery | MAX | Volt | Battery Voltage - Undefined | 2001-09-19 | 2002-10-18 | Battery max 545 |
BATT.I-1 | Battery | OBS | Volt | Undefined Sensor - Linear Equation | 2021-09-10 | present | Update to CR1000X - MR |
BATT.I-1 | Battery | OBS | Volt | Undefined Sensor - Linear Equation | 2001-09-19 | 2021-09-10 | New install |
BATT.I-2 | Battery | OBS | Volt | Undefined Sensor - Linear Equation | 2021-09-10 | present | Update to CR1000X - MR |
BATT.I-2 | Battery | OBS | Volt | Undefined Sensor - Linear Equation | 2005-10-25 | 2021-09-10 | CR10X battery current |
BATT.I-2 | Battery | OBS | Volt | Undefined Sensor - Linear Equation | 2002-10-18 | 2005-10-25 | CR10X battery current |
BATV.H-2 | Battery | AVG | Volt | Undefined Sensor - Linear Equation | 2001-09-19 | 2002-10-18 | Battery min 545 |
BATT.I-3 | Battery | OBS | Volt | Battery Voltage - Undefined | 2013-09-19 | 2024-09-25 | CR10X internal battery current |
BATT.I-3 | Battery | OBS | Volt | Battery Voltage - Undefined | 2009-10-29 | 2013-09-19 | CR10X internal battery current |
BATT.I-3 | Battery | OBS | Volt | Battery Voltage - Undefined | 2005-10-25 | 2009-10-29 | CR10X internal battery current |
BATT.I-3 | Battery | OBS | Volt | Battery Voltage - Undefined | 2002-10-18 | 2005-10-25 | CR10X internal battery current |
WDIRV.H-1 | Wind Direction | AVG | Degree | Undefined Sensor - Linear Equation | 2005-10-25 | 2024-09-25 | Wind direction hourly average |
WDIRV.D-1 | Wind Direction | AVG | Degree | Undefined Sensor - Linear Equation | 2002-10-18 | 2024-09-25 | 24 hour avg wind direction mag north |
WDIRV.D-1 | Wind Direction | AVG | Degree | Wind Speed/direction ? Unknown Sensor | 2001-09-19 | 2002-10-18 | Hourly wind direc mag degrees |
WSPDX.D-1 | Wind Speed | MAX | Mph | Undefined Sensor - Linear Equation | 2012-06-21 | 2024-09-25 | Add daily wind speed max |
WSPDX.H-1 | Wind Speed | MAX | Mph | Undefined Sensor - Linear Equation | 2005-10-25 | 2024-09-25 | Wind speed hourly max mph |
WSPDX.H-1 | Wind Speed | MAX | Mph | Undefined Sensor - Linear Equation | 2001-09-19 | 2005-10-25 | Hourly wind speed max mph |
WSPDX.H-2 | Wind Speed | MAX | Mph | Undefined Sensor - Linear Equation | 2002-10-18 | 2012-06-21 | 24 hour avg wind speed mph |
WSPDV.H-1 | Wind Speed | AVG | Mph | Undefined Sensor - Linear Equation | 2005-10-25 | 2024-09-25 | Wind speed hourly average mph |
WSPDV.D-1 | Wind Speed | AVG | Mph | Undefined Sensor - Linear Equation | 2002-10-18 | 2024-09-25 | 24 hour avg wind speed mph |
WSPDV.D-1 | Wind Speed | AVG | Mph | Undefined Sensor - Linear Equation | 2001-09-19 | 2002-10-18 | Hourly wind speed avg mph |
SRADV.H-1 | Solar Radiation - Total | AVG | Watt/m2 | Undefined Sensor - Linear Equation | 2005-10-25 | 2010-08-25 | Solar radiation hourly avg w/m2 |
SRADV.H-1 | Solar Radiation - Total | AVG | Watt/m2 | Undefined Sensor - Linear Equation | 2001-09-19 | 2005-10-25 | Hourly solar average |
SRADV.D-2 | Solar Radiation - Total | AVG | Watt/m2 | Undefined Sensor - Linear Equation | 2005-10-25 | 2010-08-25 | 24 hour solar radiation w/m2 |
SRADV.D-2 | Solar Radiation - Total | AVG | Watt/m2 | Radiation - Licor 200(x) - Sw | 2002-10-18 | 2005-10-25 | 24 hour solar radiation w/m2 |
BATN.D-1 | Battery | MIN | Volt | Undefined Sensor - Linear Equation | 2013-09-19 | 2024-09-25 | 24 hour min 545 battery |
BATN.D-1 | Battery | MIN | Volt | Undefined Sensor - Linear Equation | 2009-10-29 | 2013-09-19 | 24 hour min 545 battery |
BATN.D-1 | Battery | MIN | Volt | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-29 | 24 hour min 545 battery |
BATN.D-1 | Battery | MIN | Volt | Undefined Sensor - Linear Equation | 2002-10-18 | 2005-10-25 | 24 hour min 545 battery |
DIAG.I-1 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | Minutes on - 24 hour |
DIAG.I-2 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # of syncs from Boise |
DIAG.I-3 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # of syncs from Dugway |
DIAG.I-4 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | Total syncs |
DIAG.I-5 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # transmits from Boise |
DIAG.I-6 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # transmits from Dugway |
DIAG.I-7 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | total transmits |
DIAG.I-8 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # acks from Boise |
DIAG.I-9 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | # acks from Dugway |
DIAG.I-10 | Diagnostics | OBS | Unitless | Undefined Sensor - Linear Equation | 2011-03-28 | present | Total acks |
DIAG.I-11 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Internal bat |
DIAG.I-12 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Loaded bat |
DIAG.I-13 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Idle bat |
DIAG.I-14 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Internal temperature of radio |
DIAG.I-15 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Forward power |
DIAG.I-16 | Diagnostics | OBS | Volt | Undefined Sensor - Linear Equation | 2011-03-28 | present | Reverse power |
RHUMV.H-1 | Relative Humidity | AVG | Pct | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | Relative humidity hourly avg |
RHUMX.H-1 | Relative Humidity | MAX | Pct | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | Relative humidity hourly max |
RHUMV.H-1 | Relative Humidity | AVG | Pct | Undefined Sensor - Linear Equation | 2001-09-19 | 2005-10-25 | Hourly avg Rel.H. |
RHUMX.H-1 | Relative Humidity | MAX | Pct | Undefined Sensor - Linear Equation | 2001-09-19 | 2005-10-25 | Hourly max Rel.H. |
RHUMN.D-2 | Relative Humidity | MIN | Pct | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | 24 hour min Rel. Humid. |
RHUMV.D-2 | Relative Humidity | AVG | Pct | Air Temp/rh - Unknown Sensor | 2005-10-25 | 2009-10-15 | 24 hour avg Rel. Humid. |
RHUMX.D-2 | Relative Humidity | MAX | Pct | Undefined Sensor - Linear Equation | 2005-10-25 | 2009-10-15 | 24 hour max Rel. Humid. |
RHUMN.D-2 | Relative Humidity | MIN | Pct | Undefined Sensor - Linear Equation | 2002-10-18 | 2005-10-25 | 24 hour min Rel. Humid. |
RHUMV.D-2 | Relative Humidity | AVG | Pct | Air Temp/rh - Unknown Sensor | 2002-10-18 | 2005-10-25 | 24 hour avg Rel. Humid. |
RHUMX.D-2 | Relative Humidity | MAX | Pct | Undefined Sensor - Linear Equation | 2002-10-18 | 2005-10-25 | 24 hour max Rel. Humid. |