Public Reports Air & Water Database Public Reports Public Reports Air & Water Database Public Reports

California SNOTEL Site Summit Meadow (1052) - Hourly Sensors for

2025-April-24 NRCS National Water and Climate Center

Daily sensors report a summary value for the previous day.

Hourly sensors report a summary value for the previous hour.

Instantaneous sensors report a single observation on the hour.

Instantaneous sensors are included with both Daily and Hourly sensor selections.

Instantaneous sensors for a Daily sensor selections are the midnight observation.

The label is constructed as follows: [Ecode.Function Interval-Ordinal:Sensor Height]

*The use of a particular manufacturer's instrument does not consitute an endorsement of that instrument or manufacturer.

Label Element Unit Instrument* Ecode Function Interval Ordinal Sensor Height
WTEQ.I-1 Snow Water Equivalent In Pressure Transducer - 100" Druck WTEQ Instantaneous 1 NA
PREC.I-1 Precipitation Accumulation In Pressure Transducer - 150" Druck PREC Instantaneous 1 NA
TOBS.I-1 Air Temperature Observed Degc Air Temp - Ysi 44211a TOBS Instantaneous 1 NA
SNWD.I-1 Snow Depth In Undefined Sensor - Linear Equation SNWD Instantaneous 1 NA
SMS.I-1:-2 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SMS Instantaneous 1 -2"
SMS.I-1:-8 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SMS Instantaneous 1 -8"
SMS.I-1:-20 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SMS Instantaneous 1 -20"
STO.I-1:-2 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) STO Instantaneous 1 -2"
STO.I-1:-8 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) STO Instantaneous 1 -8"
STO.I-1:-20 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) STO Instantaneous 1 -20"
SAL.I-1:-2 Salinity Gram Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SAL Instantaneous 1 -2"
SAL.I-1:-8 Salinity Gram Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SAL Instantaneous 1 -8"
SAL.I-1:-20 Salinity Gram Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) SAL Instantaneous 1 -20"
RDC.I-1:-2 Real Dielectric Constant Unit Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) RDC Instantaneous 1 -2"
RDC.I-1:-8 Real Dielectric Constant Unit Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) RDC Instantaneous 1 -8"
RDC.I-1:-20 Real Dielectric Constant Unit Soil Moist/temp - Stevens Hydraprobe Analog (volt Out) RDC Instantaneous 1 -20"
BATT.I-1 Battery Volt Undefined Sensor - Linear Equation BATT Instantaneous 1 NA
WDIRV.H-1 Wind Direction Average Degr Undefined Sensor - Linear Equation WDIRV 1 Hour 1 NA
WSPDX.H-1 Wind Speed Maximum Mph Undefined Sensor - Linear Equation WSPDX 1 Hour 1 NA
WSPDV.H-1 Wind Speed Average Mph Undefined Sensor - Linear Equation WSPDV 1 Hour 1 NA