California SNOTEL Site Palisades Tahoe (784) - Hourly Sensors for |
2024-April-24 NRCS National Water and Climate Center |
Daily sensors report a summary value for the previous day. |
Hourly sensors report a summary value for the previous hour. |
Instantaneous sensors report a single observation on the hour. |
Instantaneous sensors are included with both Daily and Hourly sensor selections. |
Instantaneous sensors for a Daily sensor selections are the midnight observation. |
*The use of a particular manufacturer's instrument does not consitute an endorsement of that instrument or manufacturer. |
WTEQ.I-1 |
Snow Water Equivalent |
In |
150" Transducer - Druck |
WTEQ |
Instantaneous |
1 |
NA |
PREC.I-1 |
Precipitation Accumulation |
In |
150" Transducer - Druck |
PREC |
Instantaneous |
1 |
NA |
TOBS.I-1 |
Air Temperature Observed |
Degc |
Ysi Extended Range |
TOBS |
Instantaneous |
1 |
NA |
SNWD.I-1 |
Snow Depth |
In |
Unknown - Linear Equation |
SNWD |
Instantaneous |
1 |
NA |
SMS.I-1:-2 |
Soil Moisture Percent |
Pct |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SMS |
Instantaneous |
1 |
-2" |
SMS.I-1:-8 |
Soil Moisture Percent |
Pct |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SMS |
Instantaneous |
1 |
-8" |
SMS.I-1:-20 |
Soil Moisture Percent |
Pct |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SMS |
Instantaneous |
1 |
-20" |
STO.I-1:-2 |
Soil Temperature Observed |
Degc |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
STO |
Instantaneous |
1 |
-2" |
STO.I-1:-8 |
Soil Temperature Observed |
Degc |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
STO |
Instantaneous |
1 |
-8" |
STO.I-1:-20 |
Soil Temperature Observed |
Degc |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
STO |
Instantaneous |
1 |
-20" |
SAL.I-1:-2 |
Salinity |
Gram |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SAL |
Instantaneous |
1 |
-2" |
SAL.I-1:-8 |
Salinity |
Gram |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SAL |
Instantaneous |
1 |
-8" |
SAL.I-1:-20 |
Salinity |
Gram |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
SAL |
Instantaneous |
1 |
-20" |
RDC.I-1:-2 |
Real Dielectric Constant |
Unit |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
RDC |
Instantaneous |
1 |
-2" |
RDC.I-1:-8 |
Real Dielectric Constant |
Unit |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
RDC |
Instantaneous |
1 |
-8" |
RDC.I-1:-20 |
Real Dielectric Constant |
Unit |
Hydraprobe Analog (2.5 Volt) - 1 Of 4 |
RDC |
Instantaneous |
1 |
-20" |
BATT.I-1 |
Battery |
Volt |
Unknown - Linear Equation |
BATT |
Instantaneous |
1 |
NA |
WDIRV.H-1 |
Wind Direction Average |
Degr |
Unknown - Linear Equation |
WDIRV |
1 Hour |
1 |
NA |
WSPDX.H-1 |
Wind Speed Maximum |
Mph |
Unknown - Linear Equation |
WSPDX |
1 Hour |
1 |
NA |
WSPDV.H-1 |
Wind Speed Average |
Mph |
Unknown - Linear Equation |
WSPDV |
1 Hour |
1 |
NA |