Report Generator Air & Water Database Report Generator Report Generator Air & Water Database Report Generator
Skip Disclaimers
Colorado SNTL Site Culebra #2 (430) - Daily Sensors for
2025-July-02 NRCS National Water and Climate Center
Daily sensors report a summary value for the previous day.
Hourly sensors report a summary value for the previous hour.
Instantaneous sensors report a single observation on the hour.
Instantaneous sensors are included with both Daily and Hourly sensor selections.
Instantaneous sensors for a Daily sensor selections are the midnight observation.
*The use of a particular manufacturer's instrument does not constitute an endorsement of that instrument or manufacturer.
Label Element Unit Instrument* Ecode Function Interval Ordinal Sensor Height
[E.I-O:H] [E] [I] [0] [H]
WTEQ.I-1 Snow Water Equivalent In Pressure Transducer - 100" Druck WTEQ Instantaneous 1 NA
PREC.I-1 Precipitation Accumulation In Pressure Transducer - 100" Druck PREC Instantaneous 1 NA
TOBS.I-1 Air Temperature Observed Degc Air Temp - Apogee St300 TOBS Instantaneous 1 NA
TMAX.D-1 Air Temperature Maximum Degc Air Temp - Apogee St300 TMAX 1 Day 1 NA
TMIN.D-1 Air Temperature Minimum Degc Air Temp - Apogee St300 TMIN 1 Day 1 NA
TAVG.D-1 Air Temperature Average Degc Air Temp - Apogee St300 TAVG 1 Day 1 NA
SNWD.I-1 Snow Depth In Snow Depth - Sommer Ush-9 SNWD Instantaneous 1 NA
SMS.I-1:-2 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe (value Out) SMS Instantaneous 1 -2"
SMS.I-1:-8 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe (value Out) SMS Instantaneous 1 -8"
SMS.I-1:-20 Soil Moisture Percent Pct Soil Moist/temp - Stevens Hydraprobe (value Out) SMS Instantaneous 1 -20"
STO.I-1:-2 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe (value Out) STO Instantaneous 1 -2"
STO.I-1:-8 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe (value Out) STO Instantaneous 1 -8"
STO.I-1:-20 Soil Temperature Observed Degc Soil Moist/temp - Stevens Hydraprobe (value Out) STO Instantaneous 1 -20"
BATX.D-1 Battery Maximum Volt Battery Voltage - Telemetry Power System BATX 1 Day 1 NA
BATX.D-2 Battery Maximum Volt Battery Voltage - Datalogger Power System BATX 1 Day 2 NA
BATT.I-1 Battery Volt Battery Voltage - Telemetry Power System BATT Instantaneous 1 NA
BATT.I-2 Battery Volt Battery Voltage - Datalogger Power System BATT Instantaneous 2 NA
BATT.I-3 Battery Volt Battery Voltage - Datalogger Power System BATT Instantaneous 3 NA
DIAG.I-1 Diagnostics Unitless Undefined Sensor - Linear Equation DIAG Instantaneous 1 NA
DIAG.I-2 Diagnostics Unitless Undefined Sensor - Linear Equation DIAG Instantaneous 2 NA
DIAG.I-3 Diagnostics Unitless Undefined Sensor - Linear Equation DIAG Instantaneous 3 NA
DIAG.I-4 Diagnostics Unitless Undefined Sensor - Linear Equation DIAG Instantaneous 4 NA
DIAG.I-5 Diagnostics Unitless Undefined Sensor - Linear Equation DIAG Instantaneous 5 NA